Описание

  • Resolution 14 mm
  • Protective field height 1,660 mm
  • Range 6 m
  • LED indicator for weak signal
  • With plug connector M12
  • Two safety outputs (OSSD)
  • Installation material is included with the product
Protective function finger protection LED function display Transmitter Receiver
LED OKNormal operation
LED ERRORFault state
LED STOPStop state
LED TESTTest function
LED STARTStart/ restart
LED SIGNAL LOWWeak signal
Pin assignment transmitter
Plug connector (view of connection side) Pin Designation Function Conductor coloring of connection cable
1 24 V DCB Operating voltage, 24 V DC BN
2 RANGE 0 Device configuration, corresponds to the standard EN 61131-2 WH
3 0 V DC Operating voltage, 0 V DC BU
4 RANGE 1 Device configuration, corresponds to the standard EN 61131-2 BK
5 FE Function earth (must be connected to meet the EMC requirements) GY
Connector assignment receiver
Plug connector (view of connection side) Pin Designation Function Conductor coloring of connection cable
1 FO1AB Safety output, channel 1 WH
2 24 V DC Operating voltage, 24 V DC BN
3 FO1B Safety output, channel 2 GN
4 K1_K2/RESTART Feedback external contactors YE
5 SEL_A Device configuration GY
6 SEL_B Device configuration PK
7 0 V DC Operating voltage, 0 V DC BU
8 FE Function earth (must be connected to meet the EMC requirements) RD
Number of safety outputs 2 Static, self-monitoring PNP safety outputs
Resolution 14 mm
Height of the protective field 1660 mm
Height of the sensor 1713 mm
Maximum length of connecting cables 100 m
Range of the protective field 6000 mm
Dimensions 28x30 mm
Ambient temperature -20 ... 55 °C
Degree of protection IP 65 / IP 67
Installation orientation Any
Reaction time 22 ms
Connection Plug connector M12 (5-pin transmitter / 8-pin receiver)
Electrical connection ratings
Cascadable No
Muting possible In combination with external sensors and an evaluation unit
Operating voltage DC 24 V DC -20% ... +20%
Current consumption 400 mA
Power consumption
Transmitter 1 W
Receiver 2 W
LED indicator Yes
Reliability values according to EN ISO 13849-1
ESPE type 4
Performance Level PL e
PFHD 2,45x10-8
Safety Integrity Level SIL 3 / SILCL 3
Mission time 20 y
''